Previous Topic

Next Topic

c-treeACE Server for Novell Installation

  1. Insert the c-treeACE Server CD into the proper drive on a node of the Novell Network, not necessarily the Novell file server machine.
  2. If on a Win32 system, use the automatic installation. Otherwise, copy the files from the directories below /servers/NLM/ to the intended destination directory and remove the “Read-Only” attribute from the files.
  3. Activate the c-treeACE Server using the fcactvat program. See the c-treeACE Server Activation Key Card for instructions. Some c-treeACE Server OEM vendors may provide pre-activated c-treeACE Servers with their applications.
  4. Copy the activated ctsrvr.nlm to the desired directory (see the example below).
  5. To load the c-treeACE Server, type the following from the Novell Server’s Console:
load <path>\ctsrvr.nlm

Note: The c-treeACE Server for Novell places logs, status files, etc., in the root directory of the Netware file server machine by default. Unless directed to another directory, user data and index files will also be placed in the root directory. c-tree parameter files and any ctsrvr.cfg file should be placed in the NLM machine root directory.

Example

If the Novell Netware drive is loaded as drive E: on your network node, the following command copies ctsrvr.nlm from your local directory, which is assumed to be the directory where the c-tree Server was installed:

copy ctsrvr.nlm E:\SYSTEM\<path>

When the c-tree Server for Novell is loaded, it places its logs and status files in the root directory of drive E: by default. Use the SERVER_DIRECTORY keyword to change the c-tree Server working directory.

Note: When using the SPX protocol, include the CONSOLE NO_SHUTDOWN_PROMPT Server keyword to avoid trouble when unloading a c-tree Server.